The Locus Reflex Level Gauge is a highly reliable level measuring instrument designed to provide direct visual indication of liquid levels in pressurized and non-pressurized vessels
1. Product Description
The Locus Reflex Level Gauge is a highly reliable level measuring instrument designed to provide direct visual indication of liquid levels in pressurized and non-pressurized vessels. The specially designed reflex glass uses prism technology to differentiate liquid and vapor phases, allowing clear visibility even in challenging conditions.
2. Specifications
Specification | Value |
Pressure Range | Up to 50 Bar |
Temperature Range | Up to 400Β°C |
Gauge Glass | Toughened Borosilicate Reflex Glass |
Body Material | CS / SS304 / SS316 / PP |
End Connection | Flanged / Threaded |
Cover Plate | SS304 / SS316 |
Gasket | Graphite / PTFE |
Drain/Vent Connection | Β½β |
Mounting Type | Side/Top/Bottom |
Standard Compliance | ASME / DIN / IS |
Visibility Length | 500 mm β 3000 mm |
3. Working
The reflex level gauge works on the principle of light refraction and reflection. The specially designed prism glass reflects light from the vapor space and absorbs it in the liquid space. As a result:
4. Principle
Reflex glasses use optical prisms on the inner face of the glass. When light enters the gauge:
5. Assembly
6. Installation Process
7. Technical Specifications
Feature | Details |
Design Pressure | Up to 50 Bar |
Design Temperature | Up to 400Β°C |
Glass Thickness | 17 mm (typical) |
Material Compliance | ASTM / DIN / IS Standards |
Safety Features | Auto shut-off ball checks, mica protection |
Options Available | Illuminator, Frost Protection, Mica Shield |
8. Troubleshooting for Transparent Tubular Level Gauge (also applies)
Issue | Possible Cause | Solution |
No level visibility | Valve closed / clogged | Check isolation valves and clean nozzle |
Foggy or unclear glass | Dirt buildup or chemical attack | Clean with soft brush / replace glass |
Leakage at flanges | Gasket failure | Replace gasket with suitable material |
Glass breakage | Overpressure or thermal shock | Ensure pressure/temp within limits |
Level appears wrong | Improper installation angle | Check mounting and re-align gauge |
9. HS Code for Reflex Level Gauge
π¦ HS Code: 90261000
Description: Instruments for measuring or checking the flow or level of liquids.
GST Rate in India: 18%
Export Duty: Nil (Check destination country duty separately)
10. Frequently Asked Questions (FAQs)
Q1. Can Locus Reflex Level Gauges be used in corrosive liquids?
β
Yes. Locus offers SS316 / PTFE-lined body options for corrosive applications.
Q2. What is the maximum pressure and temperature it can handle?
π Up to 50 bar pressure and 400Β°C temperature with proper material selection.
Q3. What is the difference between Transparent and Reflex Level Gauges?
πΉ Transparent uses two glasses; Reflex uses a single prism glass. Reflex provides better readability.
Q4. Can we install this in horizontal tanks?
β οΈ No. Reflex Level Gauges are designed for vertical tank installation only.
Q5. Does it require power supply?
β No. It’s mechanicalβdoes not need any electrical supply.
11. Applications
Locus International Exports β Delivering precision-engineered solutions worldwide. Trusted for quality, reliability, and seamless global trade.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.